Specifications
| Model | Piri Prime |
|---|---|
| LED Technology | 5W, Mono Chip |
| LED Count | 840 |
| Wavelengths | 2 Red / 3 NIR: 630, 660, 810, 830, 850nm |
| Category | Commercial Use |
| Dimensions | 1713×415×71 mm |
| Weight | 35.0 kg |
| Beam Angle | 30 degrees |
| EMF Radiation | 0.0 μT |
| Power source | Mains Powered |
| Lifespan | 100,000 hours |
| Brightness Control | Yes |
| Timer | Yes |
| Remote Control | Yes |
| Pulse Control | Yes |
| Wavelength Group Selection | Yes |
| Preset Memory | No |
Compare with the current Piri Prime product page.
Setup & Controls
Connect the power cord to the device panel and plug it into a wall outlet, ensuring you have a stable electrical connection. Make sure that cooling air can flow freely through the treatment device by keeping all ventilation openings clear of obstructions.
Light Selection (R/NIR Button)
Press the "R/NIR" button to cycle through light modes:
- First press: Both red and near-infrared lights are on (both RED and NIR indicators light up green)
- Second press: Red light only (only the RED indicator lights up green)
- Third press: NIR light only (only the NIR indicator lights up green; near-infrared light is not visible to the naked eye)
- Fourth press: Turn off the device
NIR is invisible to the naked human eye.
Timer Settings (T Button)
Timing is not set by default. To set a specific treatment time:
- Press the "T" button once to set a 5-minute timer
- Each additional press increases the timer duration by 5 minutes (up to 30 minutes)
- Pause: Press and hold the "T" button for 2 seconds to pause
- Resume: Press and hold the "T" button for 2 seconds again to continue
Brightness Control (Sun Button)
The default light intensity is maximum brightness. To adjust:
- Press the sun button to start at the lowest brightness
- Each press increases brightness by one level
Setup & Controls — Continued
Pulse Mode (Wave Button)
Pulse is not activated by default. To enable pulse mode:
- Press the "wave" button to enable pulse mode
- Each press cycles through pulse frequencies: 10 / 40 / 73 / 146 / 293 / 587Hz
Treatment Session
Position properly
- Place the device at the recommended distance from your skin
- Ensure the red light covers the area you want to treat
Synchronization Control Function
The sync function is turned off by default. To enable:
- Place panels within 5 meters of each other
- Turn ON: Press and hold the "wave" key for 10 seconds while the panel is off until the screen shows "ON"
- Channel Selection: Press and hold the "T" key for 10 seconds while the panel is off until the screen shows "01"
- Use the "R/NIR" or "SUN" key to select the sync channel, then press "T" to confirm
- Turn OFF: Repeat the operation used to turn synchronization on
Remote Control
The remote control function is enabled by default. If you want to disable the remote control function, press and hold the "R/NIR" button for 6 seconds. The remote control uses a 23A 12V battery.
Session Guidance
Before you start
- Use the device in a dry location and keep its ventilation openings clear.
- Check your device and cable for damage before use.
- Never look directly into the LEDs. Follow the device’s eye-protection instructions.
- Stop using the device if you experience discomfort or an adverse reaction.
Distance, duration & frequency
Refer to the product page for device-specific session guidance and published measurements. If the instructions conflict, contact support before continuing.
Do not calculate session time by assuming that every panel follows a simple inverse-square relationship. Use measurements at the stated distance for your model.
Health questions
The device manual does not replace medical advice. Consult a healthcare professional if you are unsure whether light therapy is appropriate for you.
Irradiance & Coverage (Output)
Coverage Area · Distance from Panel
Scroll horizontally to see all distances.
Choose guidance for your exact device. A portable panel and a full-size panel do not have interchangeable output or coverage.
Values vary with distance and measurement method. These measurements describe light output, not a treatment prescription.
Maintenance And Safety
Storage & maintenance
- Store the device in a dry and cool place
- Avoid moisture and extreme temperatures
- Wipe the surface with a clean cloth when needed
- Ensure ventilation openings and connections are free from dust and dirt
- Avoid opening or modifying the device yourself
Recycling
When the device has reached the end of its lifespan, it should not be disposed of with regular household waste.
Deliver the device to an approved collection station for electronic waste, or follow local regulations for recycling.
About The Light
Your device uses red and near-infrared light. The wavelength values identify the light emitted; they do not, by themselves, define a session duration or guarantee a result.
- Red light
- 630 and 660 nm. Visible red light.
- Near-infrared light
- 810, 830 and 850 nm. Light that is not readily visible to the eye.
For further reading, visit Piri Red’s learning library. For your device’s measured output, see specifications.
Disclaimer
This product is not intended to diagnose, treat, cure or prevent disease. The information in this guide does not replace professional medical advice. Contact a doctor if you have questions about your health or how to use the device.
Additional Controls
Controls and optional accessories can vary by hardware revision. If your device does not show the controls described below, contact Piri Red before following the sequence.
Standard Panel Light and Remote Pairing
With the panel in the OFF state, press and hold the first key on the remote control + the control panel until you hear a beep, indicating successful pairing.
Cancel Pairing
Press and hold the first key of the control board for about 10 seconds. When the control panel displays "OF-", pairing is successfully canceled.
Wireless Synchronization (Simple Mode)
With the panel in the OFF state, press and hold the fourth key on the control panel for 10 seconds until the display shows "L-ON". To cancel, use the same method - "L-OF" cancels the connection. Note: Press and hold the keys briefly to allow the device time to receive the signal.
Cancel Buzzer Sound
With the panel in the OFF state, press and hold the third button for 10 seconds to cancel the button sound. Use the same method to turn the sound back on.
Optional electric stand: height lock
Press and hold the S and 2 buttons on the remote control simultaneously for more than 5 seconds to lock the stand height. To unlock, repeat the same process.
Wireless Synchronization (Advanced Multi-Device Sync)
Synchronize multiple devices for coordinated operation:
- Enable synchronization on all devices you want to synchronize. Turn on the sync function one by one.
- To designate a device as the host, long-press 'Synchronous working' to enter settings.
- To synchronize another device with the host, select its ID code.
- To prevent other devices from controlling this device, disable synchronization. However, this device can still control other devices in the same group.
Additional Controls
Controls and optional accessories can vary by hardware revision. If your device does not show the controls described below, contact Piri Red before following the sequence.
Standard Panel Light and Remote Pairing
With the panel in the OFF state, press and hold the first key on the remote control + the control panel until you hear a beep, indicating successful pairing.
Cancel Pairing
Press and hold the first key of the control board for about 10 seconds. When the control panel displays "OF-", pairing is successfully canceled.
Wireless Synchronization (Simple Mode)
With the panel in the OFF state, press and hold the fourth key on the control panel for 10 seconds until the display shows "L-ON". To cancel, use the same method - "L-OF" cancels the connection. Note: Press and hold the keys briefly to allow the device time to receive the signal.
Cancel Buzzer Sound
With the panel in the OFF state, press and hold the third button for 10 seconds to cancel the button sound. Use the same method to turn the sound back on.
Optional electric stand: height lock
Press and hold the S and 2 buttons on the remote control simultaneously for more than 5 seconds to lock the stand height. To unlock, repeat the same process.
Wireless Synchronization (Advanced Multi-Device Sync)
Synchronize multiple devices for coordinated operation:
- Enable synchronization on all devices you want to synchronize. Turn on the sync function one by one.
- To designate a device as the host, long-press 'Synchronous working' to enter settings.
- To synchronize another device with the host, select its ID code.
- To prevent other devices from controlling this device, disable synchronization. However, this device can still control other devices in the same group.
FAQs
How do I know I have the right manual?
Match the model on your device label. Similar names can refer to different generations. Check the model identifier and specifications for your hardware revision. If you are unsure, contact support with a photo of the label.
Why do some LEDs look dim or unlit?
Near-infrared light is not readily visible. This model uses red and near-infrared wavelengths. If you suspect a fault, contact support rather than judging output by visible brightness alone.
Where can I find session settings for this device?
Read setup & controls and session guidance. You can also consult the product page.
Can I save or print the manual?
On desktop, use Print / Save PDF in the left menu. On mobile, Share opens your device’s available sharing apps; use the browser’s Print option to save a PDF. To keep every manual and its diagrams offline, download the ZIP from the manual library.
What if an accessory is missing or the device is damaged?
Keep your order details and contact Piri Red. See the returns policy for current reporting requirements.
Warranty & Support
3-year limited warranty
The warranty covers material and manufacturing defects under normal use. Keep your proof of purchase and contact Piri Red for a claim.
30-day returns
The store’s return period runs from the purchase date. Eligibility, condition, packaging and proof-of-purchase requirements apply.
For current terms and the returns process, read the warranty, returns & refunds policy.